E.H. Price Kelowna, Mechanical Division supplies and supports commercial HVAC systems to the mechanical contractors, engineers and commercial building owners. Whether it’s a design build or bid and spec project, we integrate up-to-date technology and reliable, energy efficient products with knowledgeable support for all your HVAC applications.

Image_Kelowna_Mechanical
Carrier

CARRIER
www.carrier.com

  • Water-Cooled Chillers
    • Rotary Hermetic Centrifugal: 200 – 3,400 Tons
    • High Efficiency Variable Speed Screw: 175 – 550 Tons
    • Rotary Screw: 75 – 400 Tons
    • Packaged Scroll: 15 – 71 Tons
    • Heat Recovery and Free Cooling Options Available
  • Air-Cooled Chillers
    • Packaged Scroll: 10 – 390 Tons
    • Packaged Screw: 80 – 500 Tons
    • Remote Air-Cooled Scroll: 15 – 71 Tons
    • Remove Air-Cooled Screw: 70 – 265 Tons
    • High Efficiency Variable Screw: 140 – 500 Tons
    • Brine Capacity (+14°F to 40°F LWT)
    • Heat Recovery Options
  • Modular Chillers
    • Module Sizes for 16 – 71 Tons
    • Up to 8 Modules Can be Combined for a Total Capacity of 560 Tons
    • Heat Recovery Capability Up to 140°F (60°C)
  • Condensing Units
    • Remote Condensing Units: 5 – 182 Tons
  • Toshiba Carrier
    • 1ph Heat Pump (3, 4, 5 Tons)
    • 1ph Heat Recovery (6, 12 Tons)
    • 3ph Heat Pump (6 – 38 Tons)
    • 3ph Heat Recovery (6 – 38 Tons)
    • Inverter Driven Twin Rotary Compressors
    • Connected Capacity Up to 150%
    • DC Inverter Condenser Fan Motor
  • Carrier
    • 1ph Heat Pump (3, 4, 5 Tons)
    • 3ph Heat Pump (6 – 36 Tons)
    • 3ph Heat Recovery (6 – 28 Tons)
    • Inverter Driven Scroll Compressor
    • Connected Capacity Up to 135%
    • DC Inverter Condenser Fan Motor
  • Ducted
    • Low Static Duct: 7,000 – 24,000 Btuh Cooling
    • Medium Static Duct: 7,000 – 48,000 Btuh Cooling
    • High Static Duct: 24,000 – 53,500 Btuh Cooling
    • Vertical Duct: 12,000 – 53,500 Btuh Cooling
    • Outside Air Duct: 36,000 – 53,500 Btuh Cooling
  • Non-Ducted
    • 4-Way Cassette: 9,000 – 48,000 Btuh Cooling
    • 4-Way Compact Cassette: 7,000 – 18,000 Btuh Cooling
    • High Wall: 5,000 – 30,000 Btuh Cooling
    • Underceiling: 12,000 – 48,000 Btuh Cooling
    • Floor Console: 12,000 – 48,000 Btuh Cooling
    • Floor Recessed: 7,000 – 24,000 Btuh Cooling
  • Induction Units
    • 2 and 4 Pipe: 20 – 130 CFM
  • Pacakged Rooftop Units
    • Gas Heating/Electric Cooling Units: 20 – 100 Nominal Units
  • Dedicated Outdoor Air Units: 6 – 55 Tons
  • Indoor Self-Contained Units
    • Water-Cooled: 5 – 30 Nominal Tons
    • DX: 5 – 10 Nominal Units
  • Commercial Split Systems Over 25 Tons
    • Packaged Air-Handling Units DX: 6 – 30 Tons
    • Commerical Split System Cooling Only Single Stage: 25 – 65 Tons
    • Commercial Split System Cooling Only Dual-Circuit: 25 – 130 Nominal Tons
  • Air Handlers
    • Semi-Custom Central Station Air Handler: 1,500 – 60,500 CFM
    • Packaged Air Handling Units Chiller Water: 7.5 – 35 Tons
  • Fan Coils
    • Belt Drive Fan Coils: 600 – 4,000 CFM
    • Ducted Fan Coils: 600 – 3,000 CFM
    • Horizontal Fan Coils: 200 – 1,200 CFM
    • Stack Fan Coils: 300 – 2,000 CFM
    • Vertical Fan Coils: 200 – 1,200 CFM
    • Hydronic Cassette Ceiling Fan Coil Units: 3/4 – 3 Nominal Tons Cooling
Logo_AntecControls

ANTEC CONTROLS
www.anteccontrols.com

  • Valves
    • Venturi Valves – High Turndown Ratio and Mechanical Pressure Independence
    • Venturi FX – Measured Airflow and Low Pressure Operation
    • Integrated Venturi Valve Assembly Options
      • Performance Guaranteed Venturi with Integrated Silencer Assemblies
      • AHRI 410 Certified Venturi with Hot Water Coil Assemblies
      • UL1995 Certified Venturi with Electric Coil Assemblies
  • Monitors and Controls
    • Room Monitors
      • Touchscreen Room Pressure Monitor – High Resolution Touchscreen Display
      • Multi-Variable Monitor – High Resolution Touchscreen Displaying up to 8 Rooms on Main Screen
      • All Monitors Have Native BACnet MS/TP Connection
    • Pace™ Critical Space Controller
      • Volumetric Offset or Pressure Control
      • Temperature and Humidity Control
  • Fume Hood Controls
    • Fume Hood Controller
      • Sash Position Sensing Fume Hood Control
      • Sidewall Sensing Fume Hood Control
      • Hybrid Fume Hood Control
      • Presence Sensing
      • Fume Hood Interface
Logo_SolutionAir

SOLUTIONAIR 
www.solutionairgroup.com

  • Air-Cooled DOAS Units
    • Up to 20,000 CFM
    • Heating Options: Gas, Electric, Steam and Hydronic
    • Cooling Options: Hydronic and DX (Packaged or Split)
    • Energy Recovery Options
  • Customizable Air Handlers
    • Up to 100,000 CFM
    • Indoor / Outdoor Construction
    • Single / Double Wall Construction
    • Heating Options: Gas, Electric, Steam and Hydronic
    • Cooling Options: Hydronic and DX (Packaged or Split)
    • Energy Recovery
    • Packaged Control
  • Make-Up Air Units
    • Direct Fired: 250 – 15,000 MBH
    • Indirect Fired Drum and Tube: 200 – 6,000 MBH
    • Indirect Fired Convoluted Tube: 75 – 1,200 MBH
    • 90% Efficient Indirect Fired: 250 – 1,600 MBH
  • Rooftop Units (8 – 250 Tons)
    • Highly Configurable
    • Heating Options: Indirect Gas, Electric, Steam and Hydronic
    • Cooling Options: Hydronic and DX (Packaged Up to 160 Tons and Split Up to 250 Tons)
    • Energy Recovery Options
Logo_Greenheck

GREENHECK
www.greenheck.com

  • Direct and Indirect Gas-Fired Make-Up Air Units
  • Indoor Air Handling Units
  • Fan Coils
  • Heat Recovery Products
  • Packaged Cooling Option
  • Coils
    • Chilled Water
    • DX Evaporator
    • Condenser
    • Non-Freeze Steam Distributing
    • Booster / Duct Mounted
    • Hot Water
    • Heat Reclaim
    • Standard Steam
  • ERV – Energy Recovery Ventilator
    • 400 to 12,000 CFM
    • 1.5 in. wg external static pressure
    • Louvered intake weatherhood lowers supply air intake velocities to prevent rain and snow from being pulled into the unit
    • 2-inch outdoor and return air filters with a MERV 8 (30% efficiency) rating
    • 18 gauge outer wall construction
    • Multiple energy wheel options allow selection of a unit by what is critical in the design or application:
      • Effectiveness
      • Recovery Efficiency Ratio (RER)
      • Low blower horsepower
  • ERH – Energy Recovery Ventilator with Heating and Cooling
    • 10,000 CFM
    • 1.5 in. wg external static pressure
    • Fresh outdoor air is pre-conditioned by the total enthalpy wheel, recovering a majority of the energy from the exhaust air
    • Saves 3-4 tons of cooling per 1,000 CFM
    • Saves 50-60 MBH of heating per 1,000 CFM
    • The heating section further tempers cold outdoor air to desired conditions
    • Chilled water coils, split DX cooling, packaged DX cooling
Logo_SolutionAir

SOLUTIONAIR 
www.solutionairgroup.com

  • RegenCore Alternating Mass-Exchanger Energy Recovery Units
    • No Pre-Heat Requirements Down to Outdoor Temperatures of -40°C
    • Up to 92% Effectiveness
Logo_Lifebreath

LIFEBREATH
www.lifebreath.com

  • Inline Fans
  • Heat Recovery Ventilators
  • Turbulent Flow Precipitators
  • Clean Air Furnace
Logo_Greenheck

GREENHECK
www.greenheck.com

  • Wall, Island Proximity and Heat, Condensate Hoods
  • Internal and External Supply Plenums Optional
  • Variable Volume Control Packages
  • Ecology Odor Control Units
  • Standard Baffle Filter, High Velocity Cartridge, High Efficiency Grease-X-Tractor and Dual Stage Grease Grabber, Filtration
  • Flexconnect Utility Distribution System
    • Factory Build Wall Utility Systems Offering Single Point Connections for Gas, Water and Electricity
    • Easy to Clean Stainless Steel Exterior
    • Adds Flexibility, Easy Relocation of Equipment, Reduces Installation Time, Allows Integration of Controls and Concealment of All Pipes and Wiring
logo_NUAirLogo

NU-AIR VENTILATION
www.nu-airventiliation.com

  • Heating and Energy Recovery
    • HRVs and ERVs for Residential Applications
    • HRVs and ERVs for Commercial Applications
    • Central Air and Fan Coils
    • Air Exchangers
    • Controls and Accessories
Logo_VulcanRadiator

VULCAN RADIATOR
www.vulcanrad.com

  • Commercial Hydronic Heating Products Including:
    • Commercial Wall-Fin Radiation
    • Light Commercial Wall-Fin Radiation
    • Cabinet Unit Heaters
    • Convectors
    • Horizontal and Vertical Unit Heaters
    • Panel Radiators
    • Custom Enclosure
    • Security Enclosure
Price_Logo_Beams

PRICE INDUSTRIES LIMITED
www.priceindustries.com

  • Chilled Beams
    • Linear, Modular, Horizontal, Vertical and Floor-Mounted Active
    • Linear Passive
    • Passive with Integrated Returns
    • Controls and Hose Kits
  • Retrofit Perimeter Induction Units
Price_Logo_FanBlowerCoils

PRICE INDUSTRIES LIMITED
www.priceindustries.com

  • High Performance Fan Coils
    • Optional Integrated Silencer
    • Standard ECM Motor
  • Horizontal Blower Coils
  • Vertical Fan Coils
    • Concealed and Exposed
BryAir

BRY-AIR
www.bry-air.com

  • MiniPac®
    • Standard Sizes 100 – 1,800 CFM Process Air
    • Fully Self-Contained Unitary Design
    • Insulated Process and React Airflow Sectors
    • Dry Desiccant Rotor with Stainless Steel Flange
    • Electric Reactivation Heat System
    • Integral Volume Dampers
    • ETL Listed System Design
    • Integrated Control System
    • Optional Humidistat Control
    • Optional Pre and Post Cooling Modules
    • Optional Stainless Steel Construction
  • VFB™ and EcoDry Series
    • Standard Sizes of 300 – 30,000 CFM Process Air
    • Single or Double Wall Construction
    • Dry Desiccant Rotor with Chain Drive
    • Direct Drive Fans with Premium Motors
    • Chilled Water, Ammonia or Packaged DX Pre or Post Cooling
    • Steam, Electric or Gas Heating and Regen Options
    • Hinged Access Doors
    • Lights and Miscellaneous Power Options
    • VFD Fan Motor Control Optional
    • Reactivation Energy Recovery Options
Price_Logo_Controls

PRICE INDUSTRIES LIMITED
www.priceindustries.com

  • Application Specific Controls for:
    • Networked or Stand-Alone Applications
    • VAV / VVT Controllers (BTL Certified)
    • Mini-Front-End Solutions
  • Pneumatic Stand-Alone Controls
  • Control Applications:
    • Rooftop Controls
    • Bypass Controls
    • Single Duct Controls
    • Fan Powered Controls
    • Prodigy Smart Diffusers
    • Web Server Graphical Interface
    • Hydronic Controls
    • Underfloor Controls
Logo_FranklinControls

FRANKLIN CONTROL SYSTEMS
www.franklin-controls.com

  • HVAC Specialty Products
    • Building Automation Starters
    • Standard Automation Starters
    • Cooling Tower Controls
    • Kitchen Hood Controls
    • Pump and HVAC Controls
    • Variable Frequency Drives (VFD)
  • Industrial Products
    • Contactors and Overload Relays
    • Manual Motor Starters
    • Circuit Breakers
    • Starters
    • Soft Starters
    • Soft Starters with Integrated Bypass
    • Programmable Logic Controllers
    • Terminal Blocks
    • Pilot-Devices
    • Enclosures
Logo_Belimo

BELIMO
www.belimo.com

  • Electronic Control Valves
  • Zone Control Valves
  • Globe Valves
  • Butterfly Valves
  • Actuators
FHP-BOSCH

FLORIDA HEAT PUMPS
www.bosch-thermotechnology.us

PACKAGED UNITS & SPLIT SYSTEMS

  • LV Model: Water-to-Air Packaged Unit
    • .5 to 6 tons
    • Up to 16.9 EER (GLHP); Up to 5.3 COP (WLHP)
    • Option-rich, compact size
    • Unique sound package designed to eliminate vibration and reduce unwanted noise
  • LV Model: Water-to-Air Split System
    • 1.5 to 6 tons
    • Up to 15.9 EER (GLHP); Up to 4.4 COP (WSHP)
    • Space-saving flexible configuration, option-rich, lower operating costs, and quiet comfort
  • EP Model: Water-to-Air Packaged Unit
    • .5 to 6 tons
    • Up to 21.7 EER (GLHP); Up to 6.0 COP (WSHP)
    • Industry-leading single-stage high efficiency with a variety of options
  • ES Model: Water-to-Air 2-Stage Packaged Unit
    • 2 to 6 tons
    • Up to 24.5 EER (GLHP) and 5.4 COP (WHSP) Part Load; Up to 18.7 EER (GLHP) and 5.0 COP (WHSP) Full Load
    • Two-stage scroll compressor
    • ECM constant airflow blower motor
    • One of the industry’s most ultra-efficient units providing powerful performance and enhanced features that provide the best all around value
  • LM Model: Water-to-Air 2-Stage Packaged Unit
    • 2 to 6 tons
    • Up to 32.0 EER (GLHP) and 6.5 COP (WLHP) Part Load; Up to 22.0 EER (GLHP) and 5.6 COP (WLHP) Full Load
    • Two capacity scroll compressor
    • ECM Motor
    • Best-in-class efficiency and comfort
  • LM Model: Water-to-Air Split System
    • 2 to 6 tons
    • Up to 26.4 EER (GLHP) and 6.1 COP (WSHP) Part Load; Up to 19.3 EER (GLHP) and 5.3 COP (WSHP) Full Load
    • Flexible Configurations, and ideal for locations where space is limited, with exceptionally quiet operation
    • Fully featured
    • Two-stage scroll compressor
    • ECM Motor
    • Best-in-class efficiency and comfort
FHP-BOSCH

FLORIDA HEAT PUMPS
www.bosch-thermotechnology.us

WATER-TO-WATER UNITS

  • WT Model: Water-to-Water 2-Stage Packaged Unit (Chiller/Boiler)
    • 2 to 6 tons
    • Up to 22.1 EER (CLHP); Up to 4.7 COP (WSHP) Part Load
    • Wide range of voltages
    • Near limitless options for hydronic systems
    • Two-stage compressor and high operating temperatures for best-in-class performance
    • Two-stage reverse cycle chiller water heater designed specifically to meet high-end hydronic systems
  • WW Model: Water-to-Water 2-Stage Packaged Unit (Chiller/Boiler)
    • 10 to 35 tons
    • Up to 22.1 EER (GLHP); Up to 4.7 COP (WSHP) Part Load
    • Single-stage scroll compressor or dual scroll compressors
    • Two-stage refrigerant circuits (20 to 35 tons) for water-cooled modular reverse cycle chiller applications

CONSOLE UNIT

  • CA Model | Console Unit
    • .75 to 1.5 tons
    • High Efficiency
    • Compact size and efficient to provide comfort where space and access are limited
    • Decentralized room terminal unit that is field connected to a closed circuit piping loop

LARGE UNITS

  • EC Model | Water-to-Air Packaged Unit & Split System Large Capacity
    • 6 to 30 tons
    • Up to 24.5 EER (GLHP); Up to 5.6 COP (WSHP)
    • Dual refrigeration system
    • High efficiency unit with increased flexibility in installation and availability of applications
  • MC Model | Water-to-Air Packaged Unit
    • 30 to 60 tons
    • Up to 16.1 EER (WSHP); Up to 5.4 COP (WSHP)
    • Ultra Efficiency with value added features and multi-levels of capacity
    • Scroll compressors, variable air volume and 100% outside air capability providing flexibility, performance and quiet operation